[WELL Lab] Cleanroom Gloves: ISO Class Is Not the Only Criterion

Cleanroom glove selection works on entirely different logic from industrial gloves.

Industrial gloves answer "can it keep the hazard out". Cleanroom gloves answer "will it contaminate the environment itself".

◆ ◆ ◆

The three core cleanroom criteria

· Particle shedding: the glove must not itself be a particle source.

· Extractables: no plasticisers or residual monomers leaching out to contaminate product or process.

· Grade matching: the glove cleanliness level must correspond to the ISO Class of the area.

This is why industrial disposables cannot substitute for cleanroom gloves — even when they look similar.

◆ ◆ ◆

PHS Series: three sterile latex gloves

Our cleanroom line is the PHS series, in three models. The main differences are length and cuff design.

📄 产品资料:PHS-400 Sterile Latex Gloves (Cleanroom)

PHS-400 Sterile Latex Gloves (Cleanroom) — the base model, extended length. Suited to standard cleanroom operations requiring hand and wrist coverage.

📄 产品资料:PHS-500 Sterile Latex Gloves (Extended)

PHS-500 Sterile Latex Gloves (Extended) — longer. For scenarios needing forearm coverage, such as reaching into equipment or where liquid splash is possible.

📄 产品资料:PHS-600 Sterile Latex Gloves (Extra-Long)

PHS-600 Sterile Latex Gloves (Extra-Long) — also in the extended family, selected to match different operating habits and equipment interfaces.

All three are sterile products, for applications with microbial limits (aseptic filling, biopharma, cell handling).

◆ ◆ ◆

Choosing length

Ask whether the operation reaches into a container or equipment. Surface items only → extended (PHS-400) Forearm coverage or liquid interface → extra-long (PHS-500 / 600)

◆ ◆ ◆

Remember double-gloving

Cleanrooms typically require double gloving (inner + outer), with the outer changed periodically and the inner providing continuous protection. Selection must account for the feel when layered — too thick impairs fine manipulation.

For teams with higher latex allergy risk, a cleanroom-grade nitrile alternative should be assessed. Contact us to confirm.

◆ ◆ ◆

Further reading

Full explanation of cleanroom ISO Class: Cleanroom glove ISO Class 100 / ISO 5 explained.

Industrial (non-cleanroom) disposable selection: Nitrile, latex and PVC gloves compared.

Environmental control equipment relevant to cleanroom product safety: see Product Safety and Air Filters.

◆ ◆ ◆

延伸阅读

▸ 【维尔实验室】洁净室手套 ISO Class 100 / ISO 5 等级含义与选购要点 (中文)

▸ 丁腈、乳胶、PVC 一次性手套怎么选?材质差异与采购决策指南 (中文)

▸ [WELL Lab] PHD-018 40cm Extended Nitrile Gloves